NI 9265 Operating Instructions and Specifications

10

ni.com

You must connect an external power supply to the NI 9265. This
power supply provides the current for the devices you connect to
the module. Connect the positive lead of the power supply to the
supply terminal, V

sup

, and the negative lead of the power supply to

Power Supply COM.

When the module powers on, the channels output the startup
current. Refer to the

Specifications

section for more information

about startup current. Refer to the software help for information
about configuring startup output states in software. Visit

ni.com/info

and enter

cseriesdoc

for information about

C Series documentation.

Wiring for High-Vibration Applications

If an application is subject to high vibration, National Instruments
recommends that you either use ferrules to terminate wires to the
detachable screw-terminal connector or use the NI 9932 backshell
kit to protect the connections. Refer to Figure 4 for an illustration
of using ferrules. Refer to Figure 1 for an illustration of the
NI 9932 connector backshell.