Connecting to copper gigabit devices (WSS 2380 and WSS 2382 only)

Complete the following procedure to install a GBIC.

Step

Action

1

Insert a Cat-5 cable with a standard RJ-45 connector into the port’s copper interface.
The Cat-5 cable can use straight-through or crossover signaling.

2

Access the WSS CLI using the serial console port, as described in

“Powering on a

2380” on page 18

.

3

Enter enable to access the configuration level of the CLI.

The password to gain access to privileged mode is not set. When prompted for the
password, press Enter to continue.

4

Enter set port media-type rj45 to set the active interface on the port to
RJ-45 (copper).

5

Observe the lower LED to the left of the port:

If the LED is solid green, the 1000-Mbps link is operational.

If the LED is blinking green, traffic is active on the 1000-Mbps link.

If the LED is unlit, the link is not operational. Check the cable and verify that the
device at the other end of the link is operational.

End