Newcon Optik LRF MOD 4EC User Manual
Page 23

20
Pressing the A button will activate shown on the LCD 
communication format. 
Gating mode
In this mode the gating function is activated: user can set the 
minimal distance to the target; reflection from any object closer 
than the gating distance will be ignored. 
The Gating feature helps measuring remote targets in adverse 
atmospheric and environmental conditions by eliminating 
reflections from snowflakes, raindrops, industrial wires, 
branches, etc. At the same time, if gating distance is set 
incorrectly, you can remove the desirable object from 
measurement range. 
To enter the gating mode press the A button when
GAt
is
displayed. Minimal gating distance of 100 m will be initially set, 
further pressing the M button will increase gating distance by 
100 m up to 7,000 m. When the desired distance is reached – 
select it by pressing A button. 
The Gating distance can potentially be set longer than the 
maximum measuring range. The device will not measure 
anything then. To deactivate gating choose one of preset modes 
that do not include gating (for example: Standard1, Standard2, 
Code1, Code2, etc.). 
Note: the Gating distance can only be increased. To exit gating 
selection cycle without setting any gating distance press the M 
button 70 times or hold the M button for 2 seconds. 