Code, Std 2 – Newcon Optik LRF MOD 4EC User Manual
Page 19

16
Note: On a special request a menu of a particular unit can be 
simplified to show only required modes. 
Setup mode
To modify the Ready to Measure mode parameters: 
Enter the Setup mode.
With word Ready on the display press the M button till 
display name 
COdE
is displayed and press the A button.
Select the desired parameter modification (see table below).
Press the M button till the code name of the desired 
parameter is displayed and press A button. 
To leave the Setup mode without changing measurement 
parameters press and hold the M button for two seconds. This 
works like the computer Esc key. The rangefinder will then keep 
the last set of parameters and return to the Ready to Measure 
mode. 
Mode
Display name
Dis
tance
Sp
eed
Azimuth
Elev
ation
Retic
le
Targe
t
selection logic
Ready to 
Measure 
Ready
As set at previous session
Standard1
Std
1
m Deg Deg -¦-
Auto
Standard2
Std 2
m Mils Mils -¦-
Auto