Cd 17, Plgr – Newcon Optik LRF MOD 4EC User Manual
Page 22

19
Compass calibration
If the Module was exposed to a strong magnetic field or was not 
in use for a long time, the compass accuracy may diminish. 
To bring the compass into working condition: 
Select
Cd 17
in the Setup mode
Keeping the unit horizontally, perform one full rotation
around vertical axis within half a minute and then one full 
rotation around vertical axis with device upside down 
during half a minute. 
If one rotation does not restore calibration – perform two
rotations.
The normal compass functioning will be restored. 
Depending on the version of the on-board software, during 
calibration LCD will show either time countdown in seconds 
from 59 to 1 or flashing word CAL. 
To ensure azimuth measurement accuracy calibrate compass 
after changing the battery. 
Interface format
The unit can output measurement data via RS-232 port in either a 
proprietary protocol or in the format accepted by PLGF/DALGR. 
The selected format will be indicated on the LCD with display 
names 
PLGr
or
-PC-
.
To select the required data transfer format:
Select
PLGr
(
-PC-
) in the Setup mode
