Clearances to combustible materials, Minimum clearances to combustible material – Nordyne RL 90+ User Manual
Page 9
9
Table 3. Furnace Dimensions and Shipping Weights
Table 4. Minimum Clearances to Combustible Materials
CLEARANCES TO COMBUSTIBLE MATERIALS
This furnace is Designed Certifi ed by CSA International for the minimum clearances to combus-
tible material listed in Table 4. See the furnace name plate, located inside the furnace cabinet, for
specifi c model number and clearance information.
services both the appliance and the
carbon monoxide detector;
b. Have battery back-up power;
c.
Meet ANSI/UL 2034 Standards
and comply with NFPA 720 (2005
Edition);and
d. Have been approved and listed by
a Nationally Recognized Testing
Laboratory as recognized under 527
CMR.
3. A Product-approved vent terminal must
be used, and if applicable, a Product-
approved air intake must be used. In-
stallation shall be in strict compliance
with the manufacturer’s instructions. A
copy of the installation instructions shall
remain with the appliance or equipment
at the completion of the installation.
4. A metal or plastic identifi cation plate
shall be mounted at the exterior of the
building, four feet directly above the lo-
cation of vent terminal. The plate shall
be of suffi cient size to be easily read
from a distance of eight feet away, and
read “Gas Vent Directly Below”.
Model
Number
Furnace
Btuh
Dimensions (inches)
Shipping
Weight
(lbs)
A
B
C
D
*RC040
40,000
14 1/4
12 3/4
5 1/8
11 3/4
133
*RC060
60,000
14 1/4
12 3/4
5 1/8
11 3/4
140
*RC080
80,000
19 3/4
18 1/4
7 7/8
17 1/4
172
*RC100
100,000
19 3/4
18 1/4
7 7/8
17 1/4
180
*RC120
120,000
22 1/2
21
9 1/4
20
204
*RL040
40,000
14 1/4
12 3/4
4 5/8
12 3/4
135
*RL060
60,000
14 1/4
12 3/4
4 5/8
12 3/4
135
*RL080
80,000
19 3/4
18 1/4
10
18 1/4
174
*RL100
100,000
19 3/4
18 1/4
10
18 1/4
185
*RL120
120,000
22 1/2
21
12 1/2
21 1/8
209
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
Furnace
Cabinet
Minimum Clearances (Inches)
Input
Width
(Btuh)
(Inches)
Side
Vent
Back
Top
Front
40,000
14 1/4
0
0
0
1
1*
60,000
14 1/4
0
0
0
1
1*
80,000
14 1/4
0
0
0
1
1*
100,000
19 3/4
0
0
0
1
1*
120,000
22 1/2
0
0
0
1
1*
* When installed horizontally, 24 inches is required for servicing.