Each opening
to outside must
be at least
1 sq. in. per
4000 Btuh of
total input
rating.

12" Max

Total Input

Rating (Btuh)

40,000
60,000
80,000
100,000
120,000
140,000
160,000

Minimum

Free Area

(Each Opening)

10 sq. in.
15 sq. in.
20 sq. in.
25 sq. in.
30 sq. in.
35 sq. in.
40 sq. in.

Round Duct

Diameter

4"
5"
5"
6"
6"
7"
8"

-----

----

-----

----

Furnace

Water Heater

Vent or

Chimney

12"

Max

Figure 13. Equipment in a Confi ned

Space with all Combustion Air drawn from

Outdoors through Vertical Ducts – from

Ventilated Attic

Air Duct must be
at least 1 sq. in.
per 4,000 Btuh of
total input rating.

Ducts must
extend above
attic insulation.

Air Duct must be
at least 1 sq. in.
per 4,000 Btuh of
total input rating.

Ventilation Louvers at each end of attic

Attic

Insulation

12" Max

Total Input

Rating (Btuh)

40,000
60,000
80,000
100,000
120,000
140,000
160,000

Minimum

Free Area

(Each Opening)

10 sq. in.
15 sq. in.
20 sq. in.
25 sq. in.
30 sq. in.
35 sq. in.
40 sq. in.

Round Duct

Diameter

4"
5"
5"
6"
6"
7"
8"

Furnace

Water Heater

Vent or
Chimney

Figure 12. Equipment in a Confi ned Space

with all Combustion Air drawn from Out-

doors through Exterior Wall

Figure 14. Equipment in a Confi ned Space

with all Combustion Air drawn from Out-

doors through Ventilated Crawl Space and

Ventilated Attic

Total Input

Rating (Btuh)

40,000
60,000
80,000
100,000
120,000
140,000
160,000

Minimum

Free Area

(Each Opening)

20 sq. in.
30 sq. in.
40 sq. in.
50 sq. in.
60 sq. in.
70 sq. in.
80 sq. in.

Round Duct

Diameter

5"
6"
7"
8"
9"
10"
10"

Furnace

Water Heater

Air Duct
must be
at least
1 sq. in.
per 2000
Btuh of
total input
rating.

Vent or

Chimney

Air Duct

Air Duct

Figure 15. Equipment in a Confi ned Space

with all Combustion Air Drawn from the

Outside through Horizontal Ducts

Water
Heater

Vent or
Chimney

- - - - - - - - -

- - - - - - - - -

Furnace

Ventilation Louvers For
Unheated Crawl Space

- - - - - - - - -

Inlet Air

Ventilation Louvers
(each end of attic)

NOTE: Air open-
ings shall each
have a free area
of not less than
one square inch
per 4,000 Btuh of
the total input rat-
ing of all equipment
in the enclosure.

---

---

---

Alternate

Air Inlet

Outlet
Air