Nordyne RL 90+ User Manual

Page 21

background image

21

Combustion

Air Pipe

Exhaust

Vent

Cabinet

5'

Support System on

Vertical Rise Below Joints

Support System with

first support as close

to furnace as Possible

Upward Pitch
1/4" per Foot

Furnace Front

Straight Neoprene
Rubber Couplings
with 2 Hose Clamps*

Combustion

Air Pipe

Exhaust

Vent

Cabinet

5'

Support System on

Vertical Rise Below Joints

Support System with

first support as close

to furnace as Possible

Upward Pitch
1/4" per Foot

Furnace Front

Straight Neoprene
Couplings with
2 Hose Clamps*
(Optional - Not
Shown)

Combustion Air Inlet
2" PVC on 040/060 models,
3" PVC on 080/100 models

2" PVC
Exhaust Vent
All Models

Furnace Top

Downfl ow Furnaces

Upfl ow Furnaces

Downfl ow Furnaces

Upfl ow Furnaces

Figure 18. Furnace Pipe Adaptions

Figure 17. Vertical Venting

* These couplings are fi eld-supplied and can be used if the installation requires breakable connec-

tions in the piping. Note that a maximum of two couplings per pipe are allowed.

Combustion Air Inlet Pipe Collar
Diameter 3" for coupling or reducer

Furnace Top

2" PVC Exhaust Vent All Models