Total Input

Rating (Btuh)

40,000
60,000
80,000
100,000
120,000
140,000
160,000

Round Duct

Diameter

12"
12"
12"
12"
13"
14"
15"

Minimum

Free Area

(Each Opening)

100 sq. in.
100 sq. in.
100 sq. in.
100 sq. in.
120 sq. in.
140 sq. in.
160 sq. in.

Furnace

12" Max.

12" Max.

Water Heater

Vent or
Chimney

Each opening must
be at least 100 sq. in.
or 1 sq. in. per 1000
Btuh of total input
rating, whichever is
greater. See minimum
area per table.

Figure 11. Equipment in a Confi ned Space

with all Combustion Air drawn from Inside

Figure 10. Protective Screen for

One Pipe Installations

Protective
Screen

Upfl ow Models

Downfl ow Models

Figure 8. Furnace on a Wood Floor

Figure 9. Downfl ow Sub-Base

Dimensions

Downflow

Wood

Sub-base

Floor

Furnace

Sheet

Metal

Plenum

1 inch thick fiberglass 3 lb density

28.38"

9.25"

19.63"

3"

19.75"

or 14.25"*

or 22.50"**

2.0"

1.58"

1.50"

16.75"

or 11.25"

18.75"

or 13.25" or 21.50"*

* RL 040/060
** RL 120