Panduit TDP46H User Manual
Page 51
PANDUIT TDP4*H
GMTDPH-MAN
Page 3-25
Section 3: Configuration
The Counter Mode is accessed from the Advanced Mode. Press the
LINE key to step to the Counter Mode.
Pressing the Feed key will advance the display to the counter
selections.
The counters are identified in the display as:
HD: Head Counter (should be reset when print head is replaced)
CUT: cutter Counter
LIFE: Life counter (cannot be reset)
1. Use the LINE key to step the cursor to the desired counter, the
Head (HD) counter of the LIFE counter. The default position is
the Head counter.
2. Once the correct setting is selected, pressing the FEED key will
display the current value (in meters) stored in the counter. The
maximum number of digits displayed is 8.
3. Pressing the FEED key again will advance the counter to the
Clear mode. All counters with the exception of the LIFE counter
may be cleared.
4. Use the LINE key to select the desired setting. If you only
wanted to read the counter value, select NO. If you want to read
the counter and reset it to 0.0, place the cursor over the YES.
Once the desired setting is selected, pressing the FEED key will
advance the return you to the Counters Mode display.
5. To exit the Counters Mode, turn power to the printer off and then
back on.
COUNTERS MODE
The Counter Mode is provided to allow the user to access the internal printer counters.
TEST PRINT MODE
The Test Print MOde offers 4 different status labels for troubleshooting. If DSW3-5 is in the OFF position, the
Test Print cycle must be initiated with a Print Start signal on the EXT connector. You enter the Test Print Mode by
pressing the FEED key while powering the printer on.
ADVANCED MODE
COUNTERS MODE
COUNTERS
HD CUT LIFE
HEAD COUNTER
0.5M
HEAD COUNT CLEAR
YES NO
COUNTERS MODE
Displays the firmware during the initialization.
V 05.00.03.00
INITIALIZING