Table 1.

Configuration Options (4 of 5)

Switch

Options and Usage

Default in Bold

CTS

S2-1 & S2-2 (DSU A)
S4-1 & S4-2 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines the operation of interchange circuit CT106, Clear to Send
(CTS).

Off Off

Standard

CTS follows RTS with a fixed delay except when an alarm is detected
or a test is active, when CTS is turned off.

Off ON

Circuit Assurance

Same as standard, but CTS is also turned off when Carrier Mode Idle
codes are received.

ON Off

Follow RTS

CTS follows RTS without delay, regardless of alarms and tests.

ON ON

Forced On

CTS is forced on after a successful self-test.

RTS

S2-3 (DSU A)
S4-3 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines the operation of interchange circuit CT105, Request to
Send (RTS).

Off

Constant

The internal RTS is forced on and the DSU is in a constant data mode.
The transmitted signal is either Data Mode Idle codes or DTE data.

ON

Switched

RTS is monitored, and Carrier Mode Idle codes are transmitted when
RTS is off.

LSD

S2-4 (DSU A)
S4-4 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines the operation of interchange circuit CT109, Line Signal
Detect (LSD).

Off

Standard

LSD is on when the receive line is in data mode, and off when an alarm
is detected or Carrier Mode Idle codes are received.

ON

Forced On

LSD is forced on after a successful self-test.