Paradyne Dual DSU 7511 User Manual

Page 4

background image

4

7511-A2-GN10-10

January 1999

Table 1.

Configuration Options (2 of 5)

Switch

Options and Usage

Default in Bold

TX Timing Source

S1-2 & S1-3 (DSU A)
S3-2 & S3-3 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

The timing source for the DSU.

Off Off

DDS

For DDS, both switches must be Off.

For LADS:

Off ON

Receive

Receive means timing is derived from the line receive signal.

ON Off

Internal

Internal means timing is provided by the unit’s internal clock.

ON ON

External

External means timing is provided by the DTE.

Ten-Minute Test
Abort Timer

S1-4 (DSU A)
S3-4 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines whether user-initiated tests automatically terminate after
10 minutes.

Off

Enable

Tests terminate automatically after 10 minutes.

ON

Disable

Tests run indefinitely.

Network-Initiated
DSU Loopback

S1-5 (DSU A)
S3-5 (DSU B)

S1

S2

S3

S4

DSU A

DSU B

ON

ON

ON

ON

Determines whether the DSU responds to DSU latching loopback start
and stop sequences sent by the network. This option is applicable only
if the DDS line rate is 64 kbps clear channel.

Off

Enable

The DSU responds to loopback sequences.

ON

Disable

The DSU ignores loopback sequences.