About connectors – Panasonic WJ-ND400 User Manual
Page 38

About Connectors
38
*The error output timing is set under [Basic] on the settings menu (refer to the Setup Instructions (PDF file)).
Note:
•
During L active (Low active), the logic is enabled when the signal's voltage level is Low.
•
During H active (High active), the logic is enabled when the signal's voltage level is High.
Alarm/Control connector and Alarm Connector Timing and Polarity
Connectors
Active Time
Remarks
Alarm input
100 ms or more
L active
Alarm output
The time set on the setup menu
L active
Network error output
Until the network error is cleared, or until the [ERR] button on
the operation window (browser) is clicked.
L active
Alarm reset input
100 ms or more
L active
Emergency recording input
100 ms or more
L active
Available disk space warning output
From the time of the error occurrence until the time of the
error output duration
*
L active
HDD error output
From the time of the error occurrence until the time of the
error output duration
*
L active
Camera error output
From the time of the error occurrence until the time of the
error output duration or the camera is reset
*
L active
Error output
From the time of the error occurrence until the time of the
error output duration
*
L active
Time adjustment input/output
Input: 100 ms or more
Output: 1 s
Input/Output:
L active
Alarm suspension input
100 ms or more
L active, judged level
External recording mode switching
100 ms or more
L active
Outage detection input
5 s or more
L active
Power outage recovery completion
output
10 s or more
H active
ND400_Basic.book 38 ページ 2008年4月8日 火曜日 午後3時59分