beautypg.com

10 surge protector installation, Overview, Installation – Philips KX-TAW848 User Manual

Page 50

background image

2.2 Installation of the PBX

50

Installation Manual

2.2.10 Surge Protector Installation

Overview

A massive electrical surge can be caused if lightning strikes a telephone cable 10 m (33 ft) above ground,
or if a telephone line comes into contact with a power line. A surge protector is a device that is connected
to a CO line to prevent potentially dangerous electrical surges from entering the building via the CO line and
damaging the PBX and connected equipment.

To protect the system from electrical surges, we strongly recommend connecting the system to a surge
protector that meets the following specifications:

Surge arrestor type: 3-electrode arrestor

DC spark-over voltage: 230 V

Maximum peak current: at least 10 kA

Additionally, proper grounding is very important for the protection of the system (refer to "2.2.5 Frame
Ground Connection"
).

Many countries/areas have regulations requiring surge protection. Be sure to comply with all applicable
laws, regulations, and guidelines.

Installation

CS

Extn.

Extn. Extn. Extn.

SLT

APT

CO Line

CO Line

CO Line

Extn.: Extension line

Surge

Protector

Terminal

Board

PBX

Frame
Ground

Ground