beautypg.com

Pepper Computer Modular Computers RS485 User Manual

Page 261

background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

October 01, 1996

Page 5 - 105

5

Chapter 5 Analog Modules

O_SET_LINE_LIMIT

:

This operate call allows the user to set the open loop

detect level on the current version of the SM-ADC1.

The syntax is as follows:

:= OPERATE(, O_SET_LINE_LIMIT,

);

where

represents the analog return variable and can

be zero if the operate call is supported and the

correct

is passed or non-zero if an

error occurred.

is the variable name for the channel where the

operate call is to take effect.

is the current value in mA and calculated using

the following formula:

var = 0xFFF0 mA

0x14

O_GET_LINE_STATE

:

This operate call allows the user to check the line

state on the current version of the SM-ADC1. The

syntax is as follows:

:= OPERATE(, O_GET_LINE_STATE,

);

where

represents the analog return variable and is

zero if an open loop is detected. Otherwise it

returns 1.

is the variable name for the channel where the

operate call is to take effect.

is not used.