beautypg.com

7 smadc1deinit, 7 smadc1deinit -100, Smart i/o user’s manual – Pepper Computer Modular Computers RS485 User Manual

Page 256: Chapter 5 analog modules

background image

SMART I/O User’s Manual

October 01, 1996

©1996 PEP Modular Computers GmbH

Page 5 - 100

Chapter 5 Analog Modules

5.4.8.7 SMADC1DeInit

Syntax

error_code SMADC1DeInit(u_int8 PortNr);

Description

This function deinitialises the SM-ADC1 Module on the port PortNr by

freeing the resources tied up with it and setting all outputs and inputs to zero.

Input

u_int8 PortNr

SM-Port number to de-initialise

(from 0 to 10)

Output

error_code

SUCCESS

E_SEEK

if module not initialised

or standard OS-9 error code (refer to the OS-9

Technical Manual Error Codes Section).

Example

RetVal = SMADC1DeInit(0);

This manual is related to the following products: