beautypg.com

13 smadcgetgain, 13 smadcgetgain -79 – Pepper Computer Modular Computers RS485 User Manual

Page 235

background image

SMART I/O User’s Manual

©1996 PEP Modular Computers GmbH

March 12, 1996

Page 5 - 79

5

Chapter 5 Analog Modules

5.3.8.13 SMADCGetGain

Syntax

error_code SMADCGetGain(u_int8 PortNr, u_int8 channel,

u_int8 *pBuffer);

Description

This function checks if an SM-THERM board is fitted on the specified port

and if the channel is valid. It gets the gain amplifier setting of the ADC and

stores the value in a user defined buffer where the user has to take care that

the buffer is large enough to store the data.

Input

u_int8 PortNr

Port number to fetch the gain setting

(from 0 to 10)

u_int8 channel

Number of specified channel (0 to 3)

u_int8 *pBuffer

Pointer to an user defined buffer

Output

error_code

SUCCESS

E_MNF

If wrong type of module or no module

is fitted on the selected port

E_PARAM

If wrong channel number is specified

or standard OS-9 error code (refer to the OS-9

Technical Manual Error Codes Section).

Example

RetVal = SMADCGetGain(0, 1, &Buffer);

This manual is related to the following products: