4.3.8.9 SMREL1GetExtVcc

Syntax

error_code SMREL1GetExtVcc(u_int8 PortNr,

u_int8 *buffer);

Description

This function gets the input of the port PortNr and writes it to buffer.

If there is no external Vcc, then it returns 0, otherwise it returns 1.

Input

u_int8 PortNr

SM-Port number to get data

u_int8 *buffer

pointer to buffer where data is written

Output

error_code

SUCCESS

E_BMODE

if the module is unknown

or standard OS-9 error code (refer to the OS-9

Technical Manual Error Codes Section).