8.1.12. Auto Restart Control

1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four

minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power
supply resumes.

2. This type of control is not applicable during ON/OFF Timer setting.

8.1.13. Indication Panel

LED

POWER

TIMER

QUIET

POWERFUL

AIR SWING

Color

Green

Orange

Orange

Orange

Orange

Light ON

Operation ON

Timer Setting ON

Quiet Mode ON

Powerful Mode ON

Auto Air Swing ON

Light OFF

Operation OFF

Timer Setting OFF

Quiet Mode OFF

Powerful Mode OFF

Auto Air Swing OFF

Note:

• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode

judgment, or delay ON timer sampling.

• If Timer LED is blinking, there is an abnormality operation occurs.

8.1.14. Drain Pump Control Operation

• To drain out the condensed watar trapped in the drain pan in order to prevent the condensed water from overflowing from the

drain pan and leaking.

• Drain Pump starts to operate 10 sec. after compressor and Indoor fan ON.
• Drain Pump stop to operate 90 sec. after compressor OFF.

Drain Pump Error

Drain Pump Error occurs when:

- Within 20 minutes, the float switch is ON twice.

- Float switch is ON continuously for 2 minutes 30 seconds.

When error occurs, the timer indicator blinks and the unit stops its operation.