8.1.6. Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
—
—
O
O
O
O
O
—
—
—
Tab (rpm)
PSHI
SHI
Hi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
E15D
600
560
560
495
480
425
400
370
310
200
E18D
680
640
590
563
510
488
430
410
350
200
E21D
800
750
700
660
600
560
510
480
410
200
[Heating]
Remote Control
—
—
O
O
O
O
O
—
—
—
Tab (rpm)
PSHi
SSHi
SHi
Me+
Me
Me-
Lo
Lo-
SLo
SSLo
E15D
650
610
600
545
540
495
480
440
300
200
E18D
740
690
640
618
560
553
490
490
320
200
E21D
870
820
770
745
670
655
580
570
370
200
B. Indoor Fan Control
i. Indoor fan control operation outline
1. Cooling / Dry
20