beautypg.com

Clip connection – Paradyne 6382 User Manual

Page 39

background image

3. Using the Web Interface

6382-A2-GB20-00

April 2005

3-15

To complete the connection you must now click the Apply button. The Apply button
will temporarily save this connection. To make the change permanent, click on
Tools (at the top of the page) and select System Commands. At the System
Commands page, click on Save All.

CLIP Connection

Classical IP and ARP over ATM (CLIP) allows IP datagrams and ARP (Address
Resolution Protocol) requests and replies to be transmitted over ATM using ATM
Adaptation Layer 5 (AAL5).

To configure a CLIP connection:

Procedure

1. From the Home page, click on Setup and then click on New Connection. The

default PPPoE connection setup is displayed.

2. At the Type field select CLIP and the CLIP connection setup page is displayed.

3. Give your CLIP connection a unique name; the name must not have spaces

and cannot begin with numbers.

4. Select or enter a VPI and VCI (as supplied by your DSL service provider or

your ISP), or click in Auto PVC. (Auto PVC causes the router to perform
automatic VPI/VCI detection as defined in DSL forum TR-068.)

5. Specify the IP address and subnet mask.

6. Specify the address of the ARP server.

7. Specify the address of the Default Gateway.

8. Select the quality of service (QoS). Leave the default value if you are unsure

or the ISP did not provide this information. Depending on the QoS you select,
you may also enter:

— PCR (Peak Cell Rate)

— SCR (Sustainable Cell Rate)

— MBS (Maximum Burst Size)

— CDVT (Cell Delay Variation Tolerance)