Using the V.52 (BER) test pattern generator

To use the V.52 BER tests in conjunction with the Remote Digital Loop-
back tests (or with Local Line Loopback tests), do the following:

1. Locate the

511/511E toggle switch on the front panel of the

Model 1082 and set the toggle to the down position. This activates
the V.52 BER test mode and transmits a

511 test pattern into the

loop. If any errors are present, the local modem’s red

ER LED will

blink continuously.

2. If the above test indicates that no errors are present, move the V.52

toggle switch to the up position, activating the 511/E test with errors
present. If the test is working properly, the local modem’s red

ER

LED will blink. A successful 511/E test will confirm that the link is in
place, and that the Model 1082’s built-in 511 generator and detector
are working properly.