PE14D: Floor Model Electric Pasta Cooker
INSTALLATION
L20-293, R2 (05/11)
3
1.4. PLUMBING
CONNECTIONS
The plumbing installation should be done by a licensed plumber and must comply with local and
national codes.
1.4.1. WATER INLET CONNECTIONS
If a faucet or water fill option is equipped on your appliance connections to a potable water supply
will be required. If a single water connection is required it is recommended that the appliance is
connected to hot water supply. This will greatly decrease the time it takes for the appliance to
reach operating temperature. Prior to installation, a water treatment specialist should inspect the
water supply. Water hardness should contain no more then 2.0 grains/gallon. The pH level
should be between 6.5 and 8.0. These conditions can be obtained with the use of a properly
maintained water softener. The incoming water pressure should be between 20 psi (1.38 bars) to
60 psi (4.14 bars). For higher water pressures, a high-pressure regulator must be installed to
inlet plumbing to avoid damage caused by water hammer. The maximum allowable incoming
water temperature is 180°F (82°C). Have your water tested and record the measured values
below.
1.4.2. DRAIN
CONNECTIONS
Each tank has a drain that can be inserted into a drainage system. Each tank also has an
overflow line. The overflow connection is after the drain valve to provide an unobstructed
overflow path. The drain and overflow line for each tank may be connected together to form a
common drain line.
1.5.
ELECTRICAL
CONNECTIONS
It is advised that this power supply be plugged into a wall receptacle that is controlled by the
ventilation control. This will prevent the appliance from being operated without the ventilator on. If
your appliance requires an electrical connection, the power requirements are listed below.
Water Quality Checklist
Measured
Range
OK
Temperature
180°F (82°C) Max.
Hardness
2.0 Grains/Gal. Max.
pH
6.5 to 8.0
Pressure
20 psi to 60 psi
CAUTION
Connecting the appliance to the wrong power
supply may damage the appliance and void the
warranty.
WARNING
This appliance must be connected to a power supply having the same voltage and phase as
specified on the data plate located on the inside of the appliance door.
WARNING
A country approved all pole circuit breaker with a
minimum open contact gap of 3mm must be used
for proper installation. (CE countries)
WARNING
All copper wiring for this appliance must be made
in accordance with the wiring diagram(s) located
on the appliance.
WARNING
When water is at a high
temperature and high
pressure, excessive
splashing of hot water
may occur that could
result in injury.
Voltage/Phase
KW Amps
200VAC, single phase
11.6
58
208VAC, single phase
12.5
60
220VAC, single phase
11.4
52
240VAC, single phase
12.5
52
200VAC, three phase
11.6
33
208VAC, three phase
12.5
35
220VAC, three phase
11.4
30
240VAC, three phase
12.5
30
346/200VAC, three phase
11.6
19
380/220VAC, three phase
11.4
17
400/230VAC, three phase
12.5
18
415/240VAC, three phase
12.5
17