INSTALLATION

L20-293, R2 (05/11)

3

1.4. PLUMBING

CONNECTIONS

The plumbing installation should be done by a licensed plumber and must comply with local and
national codes.

1.4.1. WATER INLET CONNECTIONS
If a faucet or water fill option is equipped on your appliance connections to a potable water supply
will be required. If a single water connection is required it is recommended that the appliance is
connected to hot water supply. This will greatly decrease the time it takes for the appliance to
reach operating temperature. Prior to installation, a water treatment specialist should inspect the
water supply. Water hardness should contain no more then 2.0 grains/gallon. The pH level
should be between 6.5 and 8.0. These conditions can be obtained with the use of a properly
maintained water softener. The incoming water pressure should be between 20 psi (1.38 bars) to
60 psi (4.14 bars). For higher water pressures, a high-pressure regulator must be installed to
inlet plumbing to avoid damage caused by water hammer. The maximum allowable incoming
water temperature is 180°F (82°C). Have your water tested and record the measured values
below.

1.4.2. DRAIN

CONNECTIONS

Each tank has a drain that can be inserted into a drainage system. Each tank also has an
overflow line. The overflow connection is after the drain valve to provide an unobstructed
overflow path. The drain and overflow line for each tank may be connected together to form a
common drain line.

1.5.

ELECTRICAL

CONNECTIONS

It is advised that this power supply be plugged into a wall receptacle that is controlled by the
ventilation control. This will prevent the appliance from being operated without the ventilator on. If
your appliance requires an electrical connection, the power requirements are listed below.

Water Quality Checklist

Measured

Range

OK

Temperature

180°F (82°C) Max.

Hardness

2.0 Grains/Gal. Max.

pH

6.5 to 8.0

Pressure

20 psi to 60 psi

CAUTION

Connecting the appliance to the wrong power

supply may damage the appliance and void the

warranty.

WARNING

This appliance must be connected to a power supply having the same voltage and phase as

specified on the data plate located on the inside of the appliance door.

WARNING

A country approved all pole circuit breaker with a

minimum open contact gap of 3mm must be used

for proper installation. (CE countries)

WARNING

All copper wiring for this appliance must be made

in accordance with the wiring diagram(s) located

on the appliance.

WARNING

When water is at a high

temperature and high

pressure, excessive

splashing of hot water

may occur that could

result in injury.

Voltage/Phase

KW Amps

200VAC, single phase

11.6

58

208VAC, single phase

12.5

60

220VAC, single phase

11.4

52

240VAC, single phase

12.5

52

200VAC, three phase

11.6

33

208VAC, three phase

12.5

35

220VAC, three phase

11.4

30

240VAC, three phase

12.5

30

346/200VAC, three phase

11.6

19

380/220VAC, three phase

11.4

17

400/230VAC, three phase

12.5

18

415/240VAC, three phase

12.5

17