PE14D: Floor Model Electric Pasta Cooker
TROUBLESHOOTING
L20-293, R2 (05/11)
15
4.5. TROUBLESHOOTING
CHART
Note: If the circuit breaker or high temperature limit continue to trip, have the appliance
checked out by a authorized service technician.
4.6. CONTROLLER WARNING DISPLAYS
If your appliance is equipped with a temperature controller it may display the following warnings on its
display.
Problem
Probable Causes
Corrective Actions
No power to appliance.
Check main building power supply.
Circuit Breaker tripped.
Reset circuit breaker.
I/0 Switch in 0 position.
Flip I/0 switch to I position and turn
on controller.
Controller not turned on.
Turn on controller.
Controller does not
activate.
Power Cord loose or not connected. Connect power cord.
Controller displays
that it is heating but
water will not heat.
A. High temperature limit has tripped
B. Liquid level sensor is not closed
A. Reset High temperature limit.
B. Fill Tank with water to Fill line.
Display
Problem
Action
Water temperature
is low.
Wait for appliance to heat up.
Incorrect probe
reading.
Contact Authorized Service Company.
Water level is low.
Turn off appliance. Allow ample time for appliance to
cool before filling with water and turning on.
Incorrect probe
reading.
Contact Authorized Service Company.
Drain valve is open
while controller is
on.
Turn off appliance. Close drain valve before turning
appliance back on.