Model 3510 faceplate, 3500 series indicators and switches, Figure 3-1 – Paradyne 3510 User Manual
Page 24: Shows the 18 indicators and 4 pushbutton, And switches are listed in, Table 3-1, And their functions
COMSPHERE 3500 Series Data Service Units
3-2
March 1999
3510-A2-GN32-60
TEST
REM
PASS
FAIL/STR/DSBL
OK
OS/NS
TXD RXD RTS CTS DSR LSD
103
104
105
106
107
109
2.4/4.8
19.2/38.4
9.6
56/64
TP
LL
DL
RL
3510
496-12301-01
SPEED
Figure 3-1. Model 3510 Faceplate
Table 3-1
(1 of 3)
3500 Series Indicators and Switches
Name
Definition
Function
OK
Normal Operation
This green indicator lights when the DSU is
connected to the digital network or LADS and is
operating normally. It goes Off if the OS/NS
alarm indicator is active.
1
OS/NS
Out-of-Service/No Signal
This red indicator signals a network failure:
OS – Slow flash when Out-of-Service or
Out-of-Frame messages are received from
the network.
NS (No Signal) – Rapid flash when DSU is
not receiving signals from the network.
TEST
Test
This yellow indicator lights whenever the digital
network or a remote DSU initiates testing, or the
local TP, LL, DL, or RL key is pressed to start
testing. The test indicator flashes while tests are
being set up or taken down.
REM
Remote
This yellow indicator lights whenever a test
request is received from a remote DSU or the
digital network.
1
If the DSU has been placed in a Network Loopback, then both the OK and OS/NS indicators will be lit (the
TEST and REM indicators will also be lit).