4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLink line rate, symmet-
ric or asymmetric, Ethernet full auto negotiation capability (100Base-T
full or half duplex, 10Base-T full or half duplex) or limited auto sense
(only 100Base-T half duplex, 10Base-T full or half duplex).

Switch S1-1: Ethernet Auto Sense

Use switch S1-1 to configure the unit for full auto sense capability or lim-
ited auto sense capability. Full Auto sense capability consists of standard
Ethernet Auto sensing (100BaseT full duplex, 100BaseT half duplex,
10BaseT full duplex, and 10BaseT half duplex). Limited Auto sensing
capability consists on only auto sensing for 100BaseT half duplex,
10BaseT full duplex, and 10BaseT half duplex. The limited auto negotia-
tion feature is used when an Ethernet device does not comply with IEEE
802.3x (back pressure flow control) at 100M full duplex.

Switches S1-2 and S1-4: Data Rate

Use switches S1-2 and S1-4 to configure the CopperLink line rates.

Table 1:

Ethernet Auto Negotiation Selection Chart

S1-1

Setting

OFF

Full Auto Negotiation (Factory Default)

(100 Mbps, Full or Half Duplex)

(10 Mbps, Full or Half Duplex)

ON

Limited Auto Negotiation

(100 Mbps Half Duplex)

10 Mbps Full or Half Duplex)

Table 2:

Symmetric CopperLink Line Rates Selection Chart

S1-2

S1-3

S1-4

Symmetric Line Rate

ON

ON

ON

6.25 Mbps

ON

ON OFF

9.38

Mbps

ON

OFF

OFF

12.5 Mbps (Factory Default)

ON

OFF

ON

16.67 Mbps