11.5 To View The Setpoint

 Push and release the SET key to see the set point value.
 To return to normal display, press SET + UP or wait 15 seconds without pressing any key.

11.6 To Change The Setpoint

 Push

the

SET

key. The upper display will show the “St1” parameter name, while the lower display will show its

value.

 Use

the

UP

or DOWN key to cycle through the parameter names.

 Push

the

SET

key to modify a parameter value. The value starts flashing in the lower display.

 To change it push the UP or DOWN keys. Push the SET key again to confirm the value and pass to the setting

of next set point.

 Repeat the operations described at points 3, 4, 5.
To Exit: press SET + UP or wait 15 seconds without pressing any key.

NOTE:

Each point has a time out of 15 seconds. If any key is pushed within 15 seconds the controller exits the set

points programming procedure.

NOTE

: The set value is stored even when the procedure is exited by waiting the time-out to expire.

11.7 To Change Other Parameters

 Push

the

SET

and DOWN arrow simultaneously for 3 seconds.

 Select the required parameter. The name of the parameter is on the upper display; its value is on the lower

display.

 Press

the

SET

key: the value of the parameter will start blinking.

 Use

UP

or DOWN to change the value.

 Press

SET

to store the new value and move to the following parameter.

To Exit: Press SET + UP or wait 15s without pressing a key.