11.5 To View The Setpoint
Push and release the SET key to see the set point value.
To return to normal display, press SET + UP or wait 15 seconds without pressing any key.
11.6 To Change The Setpoint
Push
the
SET
key. The upper display will show the “St1” parameter name, while the lower display will show its
value.
Use
the
UP
or DOWN key to cycle through the parameter names.
Push
the
SET
key to modify a parameter value. The value starts flashing in the lower display.
To change it push the UP or DOWN keys. Push the SET key again to confirm the value and pass to the setting
of next set point.
Repeat the operations described at points 3, 4, 5.
To Exit: press SET + UP or wait 15 seconds without pressing any key.
NOTE:
Each point has a time out of 15 seconds. If any key is pushed within 15 seconds the controller exits the set
points programming procedure.
NOTE
: The set value is stored even when the procedure is exited by waiting the time-out to expire.
11.7 To Change Other Parameters
Push
the
SET
and DOWN arrow simultaneously for 3 seconds.
Select the required parameter. The name of the parameter is on the upper display; its value is on the lower
display.
Press
the
SET
key: the value of the parameter will start blinking.
Use
UP
or DOWN to change the value.
Press
SET
to store the new value and move to the following parameter.
To Exit: Press SET + UP or wait 15s without pressing a key.