beautypg.com

PVI Industries 1000 P 250A-TPL User Manual

Low no, Turbopower, Packaged water heater polyshield

background image

Product is patented in the U.S., Canada, and Mexico.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 6515 02/25/04

(800) 784-8326

• www.pvi.com

LOW NO

x

TURBOPOWER

®

• PACKAGED WATER HEATER

POLYSHIELD

®

POLYMER-LINED STORAGE TANK

TANK SERIES 250 GALLONS VERTICAL


Recovery gph

Dimensions

(inches)

Blower

Motor

MODEL

NUMBER

40° - 120°F 40° - 140°F

INPUT

Btu/h

Min. Inlet

Flow Gas

Pressure

" W.C.

SCAQMD Energy

Model No.

A B C HP Amps

Shipping

Weight

#

1000 P 250A-TPL

1000

800

800,000

4.5

8TPL

800 MBtu/h

33

8

1

1/2

7

1590

1500 P 250A-TPL

1500

1200

1,200,000

4.5

12TPL

1200 MBtu/h 50

8

1-1/4

1

14

1960

Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
With standard gas train

4" x 42" Channel skids for inputs ≤ 1000 MBtu/h.

4" x 53" Channel skids for inputs > 1000 MBtu/h.

* The information presented is for natural gas 0.6 S.G.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form #PV 6453.








STANDARD GAS PRESSURE REQUIREMENTS:

SEE TABLE FOR MINIMUM PRESSURE BY MODEL.

MAXIMUM STATIC INLET GAS PRESSURE IS 10.5" W.C.

FOR GAS PRESSURES OUTSIDE OF THIS RANGE,

CONTACT YOUR PVI REPRESENTATIVE.

VENTING REQUIREMENTS:

-.02" TO -.06" W.C. (NEGATIVE PRESSURE).

TYPE B VENTING.

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON

THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK

NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED."

STANDARD ELECTRICAL REQUIREMENTS:

VOLTAGE:

120V, 1Ø, 60 HZ., 20 AMPS.

OTHER VOLTAGES REQUIRE AN EXTERNAL

STEPDOWN TRANSFORMER.

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND

SPECIFICATION WITHOUT NOTICE.

This manual is related to the following products: