beautypg.com

PVI Industries 250N600A-TPO User Manual

Turbopower, Packaged water heater

background image

Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
"J" dimension is for the burner housing only.

Dimensions are in inches unless otherwise specified.

For standard and optional equipment, see form PV 6006.

Model

Number

Recovery gph

Input

Btu/h

Dimensions (inches)

Blower

Motor

Shipping

Weight

lbs

40°- 120°F 40°- 140°F

A

B

J

HP

Volt/Ph/

Amps

250 P 600A-TPO

250

200

199,000

28

4

17

1/3

115/1

∅/8

2270

500 P 600A-TPO

500

400

399,000

28

5

17

1/2

115/1

∅/10

2290

750 P 600A-TPO

750

600

600,000

31

6

17

1/2

115/1

∅/10

2370

1000 P 600A-TPO

1000

800

800,000

31

8

17

1/2

115/1

∅/10

2410

1250 P 600A-TPO

1250

1000

1,000,000

39

8

17

1/2

115/1

∅/10

2650

1500 P 600A-TPO

1500

1200

1,200,000

39

8

17

1/2

115/1

∅/10

2660

Gph

#2 Oil

1.4

2.8

4.3

5.7

7.2

8.6

2000 P 600A-TPO

2000

1600

1,600,000

11.4

51

10

25

1-1/2

115/1

∅/20

3100

2500 P 600A-TPO

2500

2000

2,000,000

14.3

51

10

25

1-1/2

115/1

∅/20

3120

3000 P 600A-TPO

3000

2400

2,400,000

17.1

53

12

25

1-1/2

115/1

∅/20

3130

3500 P 600A-TPO

3500

2800

2,800,000

20.0

53

12

25

5

230/3

∅/16

3160

4000 P 600A-TPO

4000

3200

3,200,000

22.8

53

12

25

5

230/3

∅/16

3210

K

41

41

41

41

41

41

41

41

51

51

51

TURBOPOWER

®

OIL

PACKAGED WATER HEATER

POLYSHIELD

®

POLYMER-LINED STORAGE TANK

TANK SERIES 600 GALLONS

PV 5440 04/05

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

(800) 784-8326

(817) 335-9531

www.pvi.com

Product is patented in the U.S., Canada, and Mexico.

VENTING REQUIREMENTS

-.02" TO -.06" W.C. (NEGATIVE PRESSURE)

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED

UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER SIZING, CONSULT VENTING SUPPLIER.

STANDARD ELECTRICAL REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE:
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN
OPTIONAL CONTROL CIRCUIT TRANSFORMER.

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN

AND SPECIFICATION WITHOUT NOTICE.

* REAR ACCESS MODULE

MODEL PREFIX

M

L

STD or OPTIONAL

250-1500

23"

8"

OPTIONAL

2000-2500

23"

16"

STANDARD

3000-4000

30"

18"

STANDARD