GPH Recovery at 40° to 120° F

245

GPH Recovery at 40° to 140° F

195

Input

Btu/h

199,000

Minimum gas inlet pressure – " W.C.

5.5

A

Cold Inlet - NPT

2

B

Hot Outlet - NPT

2

C

Drain - NPT

1

D

I - Beam Skids

3 X 34-1/2

E Overall

Depth

47

F Overall

Height

75

G

Flue Outlet Diameter

5

H

Gas Inlet - NPT

1/2

J

Motor HP 120 V, 1Ø, 60 Hz.

1/6

Motor

Amps

1.75

L

Height to Outlet

65

M

Height to Inlet

28

Approx. Shipping Weight - lbs

1070

Recoveries based on 82% thermal efficiency. ASHRAE 90.1 compliant.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see Form # PV6382.



J

C

D

2

B

H

3

1

A

G

F

L

23

M

34 1/2

E

41


STANDARD GAS PRESSURE REQUIREMENTS:

SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.

MAXIMUM STATIC PRESSURE: 9" W.C.

FOR GAS PRESSURES OUTSIDE OF THIS RANGE,

CONTACT YOUR PVI REPRESENTATIVE.

STANDARD ELECTRICAL REQUIREMENTS:

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS


VENTING REQUIREMENTS:

-.02" TO -.06" W.C. (NEGATIVE PRESSURE).

TYPE B VENTING.

THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE

VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL GAS CODE

UNDER "FAN-ASSISTED".

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND

SPECIFICATION WITHOUT NOTICE.

1. Control Enclosure
2. ASME Temperature &
Pressure Relief Valve
3. 3” NPT Handhole