DocuPen Roller Calibration Procedure

The DocuPen is factory calibrated and there should be no need to re-calibrate. We

advise you to recalibrate only if you experience poor scan quality, e.g. if your scanned

image looks disproportionally stretched (or shrunk) then you need to calibrate the

rollers.

As a rule, color calibration must be performed before roller calibration

1. Connect the DocuPen to

your computer using the USB

cable.

2. Start the Paperport soft-

ware.

3. Press and hold the left Shift

and Ctrl keys on your keyboard

and then click the Scan button

within the Paperport window.

The DocuPen Scanner Control

window will appear with the

Calibration function enabled.

4. In the DocuPen Scanner

Control Window, click on Options

and select the Calibration func-

tion. If you don't see the

Calibration function please redo

step 3.

5. In the Calibration Setup dialog window - Select Calibrate Roller and confirm by click-

ing the OK button

DocuPen Operation Manual 26

Note:

Before starting the calibration procedure please make sure that you have

downloaded our latest DocuPen PenTwain drivers. You can download the drivers

from the CD or the following link: http://www.planon.com/drivers.php

DocuPen Roller Calibration Procedure (continued)

6. You will be prompted to turn the

DocuPen ON. Press the Power On

button on your DocuPen and Click

OK in the PenTwain Dialog window

7. After the memory has been format-

ted the Calibration scanning dialog

window will appear. Please disconnect

the DocuPen from the USB cable and

position it on top of the Roller

Calibration sheet.

Please scan the sheet in B&W mode and high resolution.

8. The DocuPen will now save the Calibration image into memory. After the image is

saved, please attach the DocuPen to the USB cable. Now press the Power ON but

ton on the DocuPen and click the OK button within the Calibration scanning dialog

window.

9. The Calibration result dialog window will appear. You should see the roller calibra

tion values to the left. If the accuracy is within 96-104%, you have successfully

calibrated the rollers!

10. Finally,

click Upload

Values to pen

button in the

Calibration

result dialog

window to

send the cali-

bration result

to the

DocuPen.

You will be

prompted to

turn the

DocuPen ON.

Press the Power ON button on the DocuPen and click OK in the dialog window - this

will store the new values.

You have successfully recalibrated your DocuPen!

DocuPen Operation Manual 27

Note:

In order to perform Color Calibration you need to print out the Color

Calibration sheet. You can download the file from the installation CD or from the link:

http://www.planon.com/drivers.php. Please print the color calibration sheet on photo

paper in landscape mode.