Table 1. dte interface configuration options, Table 2. port configuration options (1 of 3) – Paradyne ACCULINK 3161 CSU User Manual
Page 7
5
Table 1. DTE Interface Configuration Options
Option
Factory 1
Factory 2
Comments/Description
DTE Port:
Enab
Enab
Enables the use of the DTE
DTE Port:
Disab
Disab
Enables the use of the DTE
Drop/Insert port.
DTE Framing:
D4
D4
Selects D4 or ESF framing format
DTE Framing:
ESF
ESF
Selects D4 or ESF framing format.
DTE Coding:
AMI
AMI
Selects AMI or B8ZS line coding
DTE Coding:
B8ZS
B8ZS
Selects AMI or B8ZS line coding
format.
0–133
0–133
Equal:
133–266
133–266
Equal:
(DTE Line
E
li
)
266–399
266–399
Provides selectable extended DTE
range capability.
(DTE Line
Equalizer)
399–533
399–533
range capability.
533–655
533–655
Extrn DLB:
(External DTE
Enab
Enab
Allows control of DLB on external
(External DTE
Loopback)
Disab
Disab
Allows control of DLB on external
contact closure.
Send Ones:
Enab
Enab
Sends all ones on channels
allocated to the network T1 on
Send Ones:
Disab
Disab
allocated to the network T1 on
LOS, LOF, or AIS.
Table 2. Port Configuration Options (1 of 3)
Option
Factory 1
Factory 2
Comments/Description
E530
E530
Port Type:
V.35
V.35
Selects the port type: EIA-530A,
Port Type:
RS449
RS449
Selects the port type: EIA-530A,
V.35, RS449, or X.21.
X.21
X.21
Base Rate:
Nx64
Nx64
Enables the port to either Nx56 or
Base Rate:
Nx56
Nx56
Enables the port to either Nx56 or
Nx64 rates.
Disab
Disab
Net DCLB:
V.54
V.54
Network-initiated DCLB, allows
DCLB t b
t ll d b i b
d
Net DCLB:
FT1
FT1
Network initiated DCLB, allows
DCLB to be controlled by inband
V.54 or FT1 (ANSI) codes.
Both
Both
5 o
(
S ) codes