12.0 Fault Finding

36

© Baxi Heating UK Ltd 2009

Fault Finding Solutions Sections

Is there 230V at:

Check all system wiring and pump

Main terminals L and N

Check electrical supply

1.

NO

Main terminal fuse

Replace fuse

Replace PCB

Display
illuminated

2.

NO

PCB - X1 connector
terminals 1,2

Check wiring

3.

NO

NO

A

B

1.

2.

C

NO

YES

Fan connections correct at fan. PCB -
X2 connector, is 230V AC across
terminals 5 & 7

Fan jammed or faulty winding

Replace PCB

Replace fan

YES

D

E20 - Temperature sensor faulty.
Cold resistance approximately
10kΩ @ 25° C
(resistance reduces with increase in temp.)

E28 - Incorrect PCB fitted

NO

E

Replace sensor or PCB (E28)

Gas at burner

Ensure gas is on and purged

Replace PCB

Replace gas valve

PCB - X3 connector is 230V AC across

terminals 1 & 2

YES

NO

NO

F

Check and correct the connection of the

tube between the venturi and gas valve

1.

2.

Service Reset

Condensate Pump does not run

On Reset is there 230V at:

PCB - X3 connector terminals 5 &
6 for at least 2 seconds

Replace PCB

NO

Condensate Pump terminals for at
least 2 seconds

Replace wiring

NO

YES

Replace Cond. Pump

Condensate Pump runs

YES

Condensate drain system blocked

Replace Float Switch

Clean condensate drain system

Replace PCB

G

Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position

voltage at PCB - X2 connector is
110V AC across terminals 2 & 5
(Note: from multimeter connect
‘common’ to 2 & ‘volts’ to 5)
Check wiring

YES

NO

Replace igniter

YES

NO

YES