beautypg.com

0 technical data – Baxi Potterton BBU 15 HE User Manual

Page 10

background image

10

© Baxi Heating UK Ltd 2009

Sedbuk Declaration For Bermuda

BBU 15 HE

The seasonal efficiency (SEDBUK) is 90.1%

This value is used in the UK Government’s
Standard Assessment Procedure (SAP) for energy
rating of dwellings. The test data from which it has
been calculated has been certified by 0087.

Appliance Category

CAT I

2H

Inlet Pressure (Natural Gas - G20)

mbar

20

Injector (Natural Gas - G20)

420 (4.2 mm)

Appliance Type

C

33

3.0 Technical Data

3.1

Bermuda HE CBBU 15 HE

NOx Class

5 (31mg/kWh)

Heat Input (Net)

Max

Min

kW

15.4

5.0

Heat Input (Gross)

Max

Min

kW

17.1

5.7

Heat Output (Non-Condensing)

Max

Min

kW

15.0

4.88

Heat Output (Condensing)

Max

Min

kW

15.7

5.25

Gas Rate

(Natural Gas - G20)
(After 10 mins)

Max

Min

m

3

/h

1.63

0.54

Electrical Supply

230V~ 50Hz

(Appliance must be connected to an
earthed supply)

Boiler Power Consumption

112W

Boiler Electrical Protection

IPX0

Boiler External Fuse Rating 3A

Connections
Gas Supply

-

15mm compression

Flow

-

22mm male copper

Return

-

22mm male copper

Weights
Packaged Boiler Carton

28 kg

Installation Lift Weight

27 kg

Flue Length

Max

Min

Metres

12.5

3.0

Dimensions
Casing Height

- 538mm

Casing Width

- 383mm

Casing Depth

- 306mm

Boiler Set Temperature

Max

Min

°C

75

25

Firefront
See the instructions supplied with the firefront for
all Technical Data