12.0 Fault Finding

35

© Baxi Heating UK Ltd 2009

Refer to Section 16.0 “Illustrated Wiring Diagram” for position of terminals and components
Central Heating - Follow operational sequence

Turn on Power Supply

Display Illuminates

Error 20 or 28 flashing

Error 158 flashing

Burner lights

Error 110 flashing
Error 131 flashing

Turn Central Heating

thermostat to Maximum.

Pump runs

Fan runs

Spark at ignition electrodes for

up to 5 seconds and for 3

attempts

Error 155 flashing

Go to section ‘A’

Go to section ‘E’

Ensure all external controls

are calling for heat

Go to section ‘J’

Go to section ‘B’

Error 160 flashing

Go to section ‘D’

Error 133 flashing

Burner does not stay alights

after 5 seconds

Error 133 flashing

Go to section ‘H’

Operation sequence

successful

If the error 110 is still flashing.

Go to section ‘I’

Fan runs at correct speed

YES

YES

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

NO

YES

YES

YES

YES

NO

NO

NO

NO

NO

Burner output modulates to

maintain the temperature set

Burner goes out

Go to section ‘C’

Ensure controls are set to

demand and verify the

contacts are closed

Error 160 flashing

Go to section ‘K’

YES

Go to section ‘G’

Turn the selector switch to

reset

Go to section ‘F’

YES

Check the Central Heating

NTC sensor

Go to section ‘E’

Fan stops after 10 seconds

Burner relights after at least 3

minutes, when the display is

less than the set temperature

(room thermostat open)

NO

NO

YES

NO

YES

YES

Press the Service Reset

switch for 5 seconds

NO

Error 125 flashing

Ensure that the system is full,

primary circulation is OK &

that there is no blockage

YES

Go to section ‘J’

NOTE: Sections ‘A’ to ‘L’

referred to in the chart

opposite are on the

following pages