beautypg.com

Baxi Potterton Solar User Manual

Page 3

background image

Potterton Solar - Solar Thermal Domestic Hot Water System

3

1.0

Commissioning of system

1.1

Commissioning - General

The Potterton Solar system uses a sealed system indirect

solar primary circuit which must be filled with the solar

heat transfer fluid provided. This is pre-diluted to the

appropriate strength (40% glycol/60%water) and should

not be diluted further. Use only the fluid supplied.

Additional canisters of solar fluid are available in 10 litre

(5119550) and 20 litre (5119549) bottles.

DO NOT

mix the fluid with other types.

The system should be filled when there is no direct

radiation from the sun. If direct radiation occurs the

collector panels should be shaded by covering them

during filling and flushing.

Although the solar heat transfer fluid is non corrosive

and biodegradable appropriate precautions should be

taken when handling.

- Wear protective gloves and goggles.

- Wash with soap and water if the fluid comes into

contact with skin.

- If fluid gets into eyes, immediately rinse with large

quantities of clear running water.

- A full safety and specification sheet can be obtained

by request.

The solar heat transfer fluid must be pumped into the

system.The pump can be electric or manual but must be

capable of producing a pressure of at least 2 bar.

The system should be thoroughly flushed to remove any

contaminants in the solar primary circuit prior to filling

with the heat transfer fluid