Potterton Solar - Solar Thermal Domestic Hot Water System

11

3.1.4 Overview: Construction of menu structure

The overview shows the whole menu structure.

According to basic adjustment and system type some

menu points may not be displayed.

Info

Program

Manual operation

Basic setting

Current collector temperature

Maximum temperature

Pump1 off / on

Collector protection function

/ Collector1

storage cylinder1

off / on

Minimum collector temperature

Storage cylinder1

Pump2 / Valve1

Collector protection

/ Collector1

Td max (Td on)

off / on

temperature

Maximum collector temperature

Storage cylinder1

Heating / Cooling / Temperature

Re-cooling

/ Collector1

Td min (Td off)

differential controller

off / on

off / on

Current storage cylinder

Maximum temperature of

Re-cooling

temperature / storage1 at bottom

storage cylinder2

temperature

Minimum storage cylinder

Storage cylinder2

Tube collector

temperature / storage1 at bottom

Td max (Td on)

off / on

Maximum storage cylinder

Storage cylinder2

Yield estimation

temperature / storage1 at bottom

Td min (Td off)

off / on

Current storage cylinder temp /

Minimum

Glycol type

storage2 at bottom / collector 2

pump rotating speed in %

Minimum storage cylinder temp /

Start temperature

Glycol percentage

storage2 at bottom / collector 2

Heating / cooling

Maximum storage cylinder temp /

Hysteresis temperature

Volume flow

storage2 at bottom / collector 2

heating / cooling Td

Current collector

Temperature differential

Controlling time in

temperature - return line

controller:

seconds

Maximum temperature of the

heating target Tmax

Current temperature

Temperature differential

Storage cylinder priority

heating / cooling /

controller:

differential controller

Minimum temperature of the

heating source

heating source Tmin

Current temperature

Temperature differential

Frost protection

frost protection sensor /

controller:

off / on

differential controller heating

Hysteresis Tdmax

target / universal measuring

point T6

Operating hours pump1

Temperature differential

Frost protection sensor

controller:

assignment

Hysteresis Tdmin

Yield storage1

Timeframe start 1,2,3 for the

Frost protection:

independent controller, 4 for the

start temperature

tube collector function

Operating hours pump2

Timeframe stop 1,2,3 for the

Independent controller

independent controller, 4 for the

assignment: Cooling, heating,

tube collector function

temperature differential

controller

Yield storage2

Set time

Sensor assignment for the

independent controller

Select basic configuration

3.0