3.1.8 Menu “Basic adjustment”

Adjustments and changes in this menu must be carried

out only by a competent installer or service engineer.
Incorrect adjustments may adversely affect the function
of controller and solar primary system.

To avoid accidental changes in menu “Basic adjustment”,

it is not editable in normal functioning but has only a

display function.To be able to carry out any changes, this

menu must be chosen within the first minute after

switching on the appliance. The basic adjustment menu is

‘blocked’ automatically one minute after if no buttons are

pressed or one minute after switching on the appliance.

3.0

Commissioning of solar controller

Indication

Description

Value

Factory

range

set-up

0 – 0

Collector protection

0 = off

0 = off

1 = on

1 – 120ºC

Start temperature for the collector protection

110..150ºC

120ºC

2 – 0

Re-cooling function (only when collector

0 = off

0 = off

protection is on)

1 = on

3 – 40ºC

Target temperature for the storage after

30..90ºC

40ºC

collector protection activity

4 – 0

Time controlled circulation with

0 = off

0 = off

tube collectors

1 = on

5 – 0

Yield estimation off/on

0 = off

0 = off

1 = on

6 – 0

Glycol types (see table below)

0...10

0

7 – 50

Glycol percentage

0 ... 100%

50

5% - steps

8 – 1,0

Volume flow: Litre per impulse - flow meter

0,5 ... 25 I/I

1,0

0,5l - steps

9 – 240

Time controlling in s

30...480

240

10 – 1

Storage priority

1...2

1

11 – 0

Frost protection on/off

0 = off

0

1 = on

12 – 6

Sensor assignment - Frost protection

1...6

6

13 – 3

Start temperature for the frost protection function

-20ºC ... +7ºC

3

14 – 0

Select cooling thermostat

0 = off

0

or temperature differential controller

1 = cooling

2 = heating

3 = temperature

differential controller

15 – 5

Sensor assignment for the independent controller (source)

1...6

5

16 – 0

System configuration

0...4

0

Glycol types (point 6):

0

Anro

6

Tyfocor L5.5 - supplied

1

IIexan E, Glythermin

7

Dowcal 10

2

Antifrogen L

8

Dowcal 20

3

Antifrogen N

9

Dowcal N

4

IIexan E

10

Tyfocor LS

5

IIexan P

Parameter / value