beautypg.com

Pitco Frialator Electric Fryers SEH Series User Manual

Page 9

background image

L20-246 Rev 4 (05/13)

WARNING

At operating temperature, the shortening in
the fryer may be hotter than 375°F (190°C).
This hot, melted shortening will cause severe
burns. Do not let the hot shortening touch
your skin or clothing. Always wear insu-
lated oil-proof gloves when working on the
filter system. It will be easier and safer if
the filter assembly has cooled to room tem-
perature before handling any filter parts.

a.

With the filter pan empty of oil, remove the

filter media by grasping the filter pan handle

and gently pull the assembly toward the front

of the fryer.

b.

Separate the filter pickup tube from the filter

pickup screen assembly by pulling up on the

pickup tube just above where it connects to

the pickup screen assembly. Lift pickup tube

and swing it to the left, until it rests on the left

hand side of the filter pan.

c.

Grab filter screen pickup assembly lift

handles and carry it to a trash barrel and

shake off heavy discard any debris that may

be built upon the top of the assembly.

d.

Unscrew the filter paper clip bracket from

the filter paper support screen and slide the

filter paper support screen out of the filter

paper clip bracket.

e.

Remove filter paper support screen from the

filter envelope.

f.

All of the filter pick up assembly parts can be

washed in a dish washer or a pot sink. Flush

out the suction tube assembly with hot water.

After cleaning, it is very important to thor-

oughly dry the parts before reassembling.

Water and oil do not mix. Water in hot oil

will cause the oil to splatter.

g.

Start reassembling the filter pick up assembly

by sliding the new filter paper on to the filter

paper support rack. Ensure that the hole in

the filter paper goes over the pick up tube

assembly threaded connector.

h.

Fold the open end of the bag in two folds.

The first fold should be approximately 1

inch from the end and the second should be

over the edge of the rack assembly.

i.

Slide the clip screen over the folded end of

the filter paper. Ensure the opening of the

clip screen goes over the pick up tube

connection. Screw the suction tube con-

nection onto the threaded connection.

j.

Place the filter pickup assembly into the

filter pan and slide the filter pan assembly

back into the fryer cabinet.

k.

Filter unit is now ready for use.

