TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

CORRECTIVE ACTION

Computer does not come on

A. Main circuit breaker is

A. Locate the correct building circuit breaker

nothing shows in either display

turned off

and turn OFF and back ON again.

B. Fryer fuse is blown

B. Call an Authorized Service Technician

Computer heat light comes on

A. If the oil is hot the

A. Allow the oil to cool, reset the Hi Limit and

but elements do not heat

Hi - Limit may be tripped

turn the computer OFF and back ON

again.

Computer display shows

A. Bad computer

A. Locate the correct building circuit breaker and

"OFF" and cannot be turned

turn OFF and back ON again. If this does not

"ON".

reset the computer call an Authorized Service

Technician.

RED return valve is open no

A. RED return valve not fully

A. Pull slightly on the RED return valve handle

pump sound can be heard

open

B. Filter circuit breaker may be B. Locate the filter circuit breaker behind the door

tripped

of the left hand fryer and reset it.

C. Filter motor Thermal Over-

C. Push RED reset button located on end of filter

load may be tripped

motor, behind the door of left hand fryer.

D. Sensor switch may be loose

D. If the mounting screws are loose try to tighten

them, if this is not possible call an Authorized

Service Agency.

Drain valve is closed and

A. GREEN drain valve is not

A. Apply a little more pressure to close the valve

the computer has been

fully closed

reset but still shows

B. Sensor switch may be loose

B. If the mounting screws are loose try to tighten

"DRAINING" or

them, if this is not possible call an Authorized

"TURN OFF"

Service Agency.

Drain valve is open, the oil is

A. GREEN drain valve is not

A. Apply a little more pressure to open the valve

draining slowly or not at all.

fully open

B. Drain is plugged with debris B. Use the clean out rod to clear the drain valve

from inside the fry vat. If this does not clear the

blockage, CLOSE the GREEN drain valve and

follow the instructions for clearing the main

drain line.
CAUTION:

Some HOT oil may come out when the cap is

removed.

Remove the two wing nuts from the end cap

(do NOT lose these.) Use the clean out rod to

clear the main drain tube. Install the end cap

along with its gasket and four screws. Do not

overtighten these screws or remove drain "T"

cleanout access covers, by removing thumb

screws (do not loose screws). Then clean drain,

replace access cover and thumb screws.