FILTER PROCEDURES FOR
ENVELOPE PAPER FILTER SYSTEMS

NOTE

When working with hot oil ALWAYS wear

oil-proof, insulated gloves.

WARNING

NEVER • Run the filter system without a
filter bag/paper.

NEVER • Empty the oil from the fryer
before turning OFF the fryer burners.

NEVER • Store the UFM Filter Unit
anywhere other than in the fryer filter
cavity.

a.

Slide the filter pan out. Carefully remove

filtered residue off the filter media. Examine

the filter media for clogged or torn areas.

Refer to filter media replacement instructions

following this section. Reinstall the pan.

b.

Turn the fryer that is to be filtered OFF (See

Standby Shutdown). Remove the baskets

from the fryer tank(s). Use the clean out

brush to lift out the tube screens. If there are

excess crumbs in the fryer tank, remove them

with the crumb scoop.

c.

If you have replaced the filter media or

remove crumbs and debris, sprinkle Precoat

Filter Aid on the filter paper.

d.

Check the drain spout to ensure that it is in

the drain tower and over the filter pan open-

ing.

e.

Slowly open the green handled drain valve

for the tank being filtered. If necessary use

the clean-brush to clear the crumbs from the

drain. Use the brush to clean the sides of the

tank as the oil drains.

f.

Slowly open the green handled drain valve

for the tank being filtered. If necessary use

the clean-brush to clear the crumbs from the

drain. Use the brush to clean the sides of the

tank as the oil drains.

WARNING

This filter pan is only large enough to hold the

contents of one (1) tank at once, during the

filter process.

g.

When the tank is empty, close the green handled

drain valve. Open the red handled return valve

to the tank you are filtering. This will start the

pump and return the oil to the bottom of the fry

tank.

h.

When bubbles are seen coming out of the oil

return spout, close the red handled valve to turn

the pump off.

If necessary add more oil to the tank to return

the oil level to the fill mark. The fryer is now

ready for use.

DRAINING A TANK

The filter system is also used to drain the fryers. You will

need a container capable of holding 400

0

F oil and protec-

tive gloves.

a.

Rotate the drain down spout so that it extends in

the container that you want to drain the shorten-

ing into.

b.

Open the green handled drain valve for the tank

to be drained. The oil will drain into the con-

tainer you have chosen. When the container is

full or the fry tank is empty, close the green

handled drain valve. If the container was full

repeat this step until fryer tank is empty.

c.

Once tank is completely empty add new

shortenning and follow fryer start up proce-

dures.

WARNING

The power supply

must be disconnected
before servicing or
cleaning the appliance.

FILTER MEDIA REPLACEMENT

The filter module stores neatly under the fryer when not

in use. The unit is very easy to use and allows for quick

installation and filtration, even under the busiest condi-

tions. Follow the procedures below to change the filter

media.