8 initial setting 1 – Pentax R-315EX(NX) User Manual
Page 50
50
8.7 Example of changing an initial setting content
(selection of atmospheric correction)
This section describes the operating procedures for selecting “1.ATM CORR” in Initial
Setting 1 as an example of changing an Initial Setting content. Use this example as a
reference when changing other items because it is also applicable to the operating
procedures for changing them.
Access the screen for Initial Setting 1 by taking
procedures “8.2 Entering the Mode
for Initial Setting 1”.
Press [F5] [SELECT] to open the screen for
selecting the atmospheric correction.
Press [F3] [
] or [F4] [
] to position the cursor
at the desired item, then press [ENT] key to select
that item.
Pressing the [ENT] key settles the change of
selected item. Pressing the [ESC] key invalidates
the change of selected item.
Pressing again the [ESC] key or [ENT] key quits the
initial setting screen and usual start screen appears.
8.8 Initial setting 1
1. Selection of Atmospheric Correction: [ATM CORR]
Select whether Atmospheric Correction is to be performed by
using the automatic measurement correction function with a
atmospheric sensor, by entering the atmospheric temperature
and pressure measured with a thermometer and barometer,
by entering ppm value, or by fixing the ppm value to 0 (NIL) not
to perform Atmospheric Correction.
SELECT
SET 1
1. ATM CORR
:
AUTO
2. PRISM CONST
:
0mm
3. SHEET CONST
:
0mm
4. CRV/REF CORR :
0.14
5. COMP AXIS
:
NIL
SELECT
SET 1
1. ATM CORR
:
1. AUTO
2. PRISM CONST
:
2. ATM INPUT
3. SHEET CONST
:
3. ppm INPUT
4. CRV/REF CORR :
4. NIL
5. COMP AXIS
:
NIL
SELECT
SET 1
1. ATM CORR
:
1. AUTO
2. PRISM CONST
:
2. ATM INPUT
3. SHEET CONST
:
3. ppm INPUT
4. CRV/REF CORR :
4. NIL
5. COMP AXIS
:
NIL
SELECT
SET 1
1. ATM CORR
:
ATM INPUT
2. PRISM CONST
:
0mm
3. SHEET CONST
:
0mm
4. CRV/REF CORR :
0.14
5. COMP AXIS
:
NIL
1. AUTO
2. ATM INPUT
3. ppm INPUT
4. NIL