Pentax R-315EX(NX) User Manual
Page 47
47
Press [F4] [
] to move the cursor to “3. ppm”
and press the [F5] [SELECT] to enable
the temperature to be changed.
Press the [CLEAR] key.
Input 31 by pressing numeric keys.
Pressing the [ESC] key returns the instrument
to mode A.
•
The valid range of ppm values is from -199 to +199.
•
Once set, the ppm value is displayed at the center of the top of the measurement
screen.
•
The factory initial of ppm value is “1. AUTO”.
•
Once set, the ppm value remains in memory even after the power is turned off.
CLEAR
CORRECTION
1. PRISM CONST *
0mm
2. SHEET CONST *
0mm
3. TEMP
*
0mm
4. PRESS
*
0mm
5. ppm :
+000ppm
CLEAR
CORRECTION
1. PRISM CONST *
0mm
2. SHEET CONST *
0mm
3. TEMP
*
0mm
4. PRESS
*
0mm
5. ppm :
+0 31ppm
H.angle
H.dst.
V.dst.
MEAS TARGET
0 SET DISP MODE
MODE A
15°C
S 0
92° 30’ 20”