Perle PoE/PoE+ Ethernet Media Converter

Installation Guide

15

Bank 2

PSE Enable Copper-1 (Switch 1, 2)
PSE Enable Copper-2 (Switch 4, 5) (dual
copper models only)

Switch Position 1, 4

Switch Position 2, 5

Type

Up (default)

Up (default)

PSE enabled
normal detection

Up

Down

PSE enabled
High capacitance
detection

Down

Up

PSE enabled
Legacy device
detection

Down

Down

PSE disabled

These switches must be set in order to enable the power sourcing
function and to indicate the type of device detection required. If the
device type is unknown, the default should be used as per
IEEE802.3af/at standards.

Enabled: When enabled, the media converter will perform Power
Sourcing Equipment (PSE) functions as per IEEE802.3af (POE) or
802.3at-2009 (POE+) standards.

Disabled: When disabled the media converter will not perform
PSE functions.

PD Power Reset 1 (Switch 3)
PD Power Reset 2 (Switch 6) (dual copper
models only)

Switch Position

Mode

Up (default)

Disabled

Down

Enabled

Disabled: When disabled, the loss of fiber link has no effect on
PSE power to the PD device.

Enabled: When enabled, if the media converter detects loss of link
on any fiber port it will turn off PSE output power to the PD device