beautypg.com

Perle Systems 1700 User Manual

Page 41

background image

Applications

35

Quick Start Frame Relay

Since the P1705 & P1730 auto-learns the frame relay configuration, only a couple of

parameters need to be configured before the unit is fully operational as an IP router for

frame relay.

Upon initial start up, the P1705 & P1730 are pre-configured to query the frame relay

service to auto-learn the LMI type and the PVC DLCI numbers. The P1705 & P1730

will then automatically create a remote site profile for each PVC.

Within each of the remote site profiles automatically created Bridging, IP routing, and

IPX routing are all set to “enabled”. Because each of these options are enabled by default

and the automatically created remote site profiles will establish a PVC connection to the

remote site routers, the P1705 & P1730 will bridge and IPX route data without any user

configuration. Because an IP router requires an IP address, the router must be

configured with an IP address before IP routing is fully operational.

To configure an IP address for the P1705 & P1730, use the IP address option.

IP Address

Location: Main

ª

Configuration

ª

LAN Set-up

ª

LAN IP Set-up

ª

IP Address / mask size

If security is required for the PVC connection refer to the Configure PPP Security section

for information on setting the security passwords and user names for PPP.

By default, PPP is disabled for each of the newly created remote site profiles. If PPP

encapsulation is desired, for example to use security, the PPP encapsulation option

should be set to “enabled”. By default, when PPP encapsulation is enabled multilink is

also enabled.

PPP Encapsulation

Location: Main

ª

Configuration

ª

WAN Set-Up

ª

Remote Site Set-Up

ª

Edit Remote Site

ª

Connection Set-up

ª

PPP

Enabled