beautypg.com

Pioneer DRM-7000 User Manual

Page 40

background image

40

En

Operation

NOTES:
¶ If the changer interface cable has not been properly

connected, the changer will not be able to recognize the
drive at all. You should check the wiring monitor indicator
located on the back of the drive. When the cables have
been properly connected, the indicator ought to be flashing.
= If the indicator is lit, check to make sure that the changer

interface cable of the drive in question has been properly
connected.

= If the indicator is not lit, check to make sure that the

power cable of the drive in question has been properly
connected. If the cables need to be reconnected,
reconnect the power cable before reconnecting the
changer interface cable.

¶ If the drive is recognized but the model name of the drive

is not displayed in the lower half of the LCD message
window, disconnect all three cables and reconnect them
again.
Order in which cables are to be disconnected:

1. SCSI interface cable
2. Changer interface cable
3. Power cable

Order in which cables are to be reconnected:

1. Power cable
2. Changer interface cable
3. SCSI interface cable

9. To view the settings for all drives which have been

recognized, press the ENT key to proceed to the next
layer in the message display.
¶ The SCSI ID, termination switch setting, and unique

device ID of each drive will be read in and displayed at
the same time on the same message window.

¶ If four drives have been connected in a daisy chain

configuration and termination has been turned on for
the fourth drive in the chain, the messages displayed
will be as indicated below.

Press the ENT key

Press the ESC key to return to the previous message

and then press the

» key

Press the ENT key

Press the ESC key to return to the previous message

and then press the

» key

Press the ENT key

Press the ESC key to return to the previous message

and then press the

» key

Press the ENT key

NOTES:
¶ If the SCSI IDs or termination switch settings displayed

differ from those which set on the backs of drives, or if a
drive’s device ID fails to be displayed, it is likely that the
corresponding cables were improperly connected. If this
happens, follow the steps outlined below to properly
reconnect all the cables.
Order in which cables are to be disconnected:

1. SCSI interface cable
2. Changer interface cable
3. Power cable

Order in which cables are to be reconnected:

1. Power cable
2. Changer interface cable
3. SCSI interface cable

¶ If the device ID of a drive cannot be read, then it will be

impossible for the host computer to perform automatic
configuration.

10.Press the ESC key several times to return to user mode

and close the rear access door.

Press the ESC key

This manual is related to the following products: