background image

Line Commands

42

IOLAN DS1/TS2 CLI Reference Guide, Version 4.1

lock

When enabled, the user can lock his terminal with a password using the

Hotkey Prefix

(default Ctrl-a)

^a l

(lowercase L). The IOLAN prompts the user for a password and a

confirmation.

mode

Enables/disables the line (available only on the TS2 model). The default is enabled.

modem-name

The name of the predefined modem that is used on this line.

motd

Enables/disables the message of the day on the line.

nouser

Blanks out the User parameter, in case you want to change a dedicated user line to an

undedicated line.

pages

For

DSLogin

line service, this is the number of video pages the terminal supports. Valid

values are 1-7. The default is

5

pages.

parity

Specifies if you are using

Even

,

Odd

, or

No parity

on the line. If you want to force a

parity type, you can specify

Mark

for 1or

Space

for 0.

phone-number

The phone number to use when

Connection Method

is set to

Dial Out

.

reset

Resets the terminal type connected to the line when a user logs out.

rev-sess-security

Enables/disables login/password authentication, locally or externally, on reverse Telnet

connections. The default is

Off

.

send-name
When enabled, the port name will be sent to the host upon session initiation

.

Default: Disabled

session strings
Controls the sending of ASCII strings to serial devices at session start and session
termination as follows;

z

Send at Start—If configured, this string will be sent to the serial device when the

serial device is detected (i.e. signals come up). The maximum size of this field is
128 bytes/characters.

z

Send at End—If configured, this string will be sent to the serial device when the

TCP session on the LAN is terminated. The maximum size of this field is 128
bytes/characters

z

Delay after Send—If configured, will inset a delay( in milliseconds) after the

string is sent to the device. This delay can be used to provide the serial device with
time to process the string before the session is initiated or terminated.

Default: 10 ms