Cooling Kit

For outdoor applications, a cooling kit may be desired to prevent excessive heating of the LCD display.

In direct sunlight, the front surface of the display (the LCD cell) may reach temperatures well above the

ambient temperature. Possible effects of extreme surface temperatures include:

• LCD polarizer damage (permanent degraded image)

• LCD fluid clearing (display unreadable)

• Latent image (image burn-in visible)

• Flicker (image jitter)

• Localized non-uniformity (permanent spotty appearance).

The cooling kit consists of a rear-mounted housing containing three fans and a front-mounted baffle

that channels the air flow across the display surface. The fans' speed is governed by a temperature sen-

sor adjacent to the photo sensor that is mounted on the front of the monitor. At temperatures above

15°C the fans will turn on at low speed and reach maximum speed at 25°C, thus minimizing the effects

of sun loading and high temperatures.

The total fan kit power consumption is approximately 3.6 watts with fans at max speed. Fan power is

derived from the 12V input (4-pin DIN connector.)