beautypg.com

Function menus, Continued) – Panasonic AJ-HD1800P User Manual

Page 79

background image

79

Function menus

(continued)

<50P IN/OUT ASSIGN> (continued)

50-pin assignment factory settings

__

” denotes that nothing is subject to control or to a status.

z For a command, input TTL level signals; for an active low

edge, input an electrical signal of 100 ms or more.

z For a status, a maximum open collector and sink current of

6 mA is output.

Pin no.

I/O

Setting item

1

I

REC

2

I

PLAY

3

I

FF

4

I

REW

5

I

STOP

6

I

__

7

I

__

8

I

422 REMOTE ON

9

I

422 REMOTE OFF

10

I

LOCAL ENABLE

11

I

EJECT

12

I

IN SET

13

I

REC INH ALL

14

I

REC INH PRE

15

I

LOCAL DISABLE

16

I

TC EXT

17

I

TC INT&TCG MODE AUTO

18

I

__

19

I

__

20

I

STNDBY ON/OFF

21

O

ERR0 STATUS

22

I

__

23

I

CUE

24

O

ERR1 STATUS

25

I

__

26

Power

supply

27

O

REC STATUS

28

O

PLAY STATUS

29

O

FF STATUS

30

O

REW STATUS

31

O

STOP STATUS

32

O

422 REMOTE STATUS

33

O

EJECT STATUS

34

O

ERR2 STATUS

35

O

TC SRC1 STATUS

36

O

TC SRC2 STATUS

37

O

__

38

O

__

39

O

REC INH1 STATUS

40

O

REC INH2 STATUS

41

O

CUE STATUS

42

O

REMOTE STATUS

43

O

__

44

O

PRE CTL DETECTED STATUS

Pin no.

I/O

Setting item

45

O

LOCAL ENABLE STATUS

46

O

STANDBY ON STATUS

47

GND

48

O

__

49

GND

50

GND