beautypg.com

Hid-dynavision son and cdo, Inrush current, Electrical data – Philips 220-230-240V User Manual

Page 109: Ordering and packing data

background image

OEM Catalogue 2009/2010

3.109

HID Gear

D1

A2

B1

B2

A3

A1

C1

HID-DV

Type

A1Nom

A2Nom

A3Nom

B1Nom

B2Nom

C1Nom

D1Nom

HID-DynaVision 1-10V SON/CDO

150.0

134.0

136.0

90.0

70.0

40.0

4.5

HID-DynaVision SON and CDO

Inrush current

Type

Maximum

gear number

on MCB

(x)

Inrush

current

Peak

(A)

Inrush

current

Width

(ms)

HID-D 1-10V 100/150 SON/CDO

8

50

0.5

HID-D 1-10V 70 SON/CDO

12

35

0.5

Electrical data

Type

Number

of

Lamps

(x)

Rated

Gear-

Lamp

Power

Line

Frequency

(Hz)

Line

Voltage

(V)

T-case

life

(ºC)

T-case

maximum

(ºC)

T-ambient

Ignition

Voltage

(kV)

Cable-Cap

outputwires

mutual

(pF)

HID-D 1-10V 100 /S CDO 220-240V

1

100

50/60

220-240

90

100

50

4.00

200

HID-D 1-10V 100 /S SON 220-240V

1

100

50/60

220-240

90

100

50

4.00

1000

HID-D 1-10V 150 /S CDO 220-240V

1

150

50/60

220-240

90

100

45

4.00

200

HID-D 1-10V 150 /S SON 220-240V

1

150

50/60

220-240

90

100

45

4.00

1000

HID-D 1-10V 70 /S CDO 220-240V

1

70

50/60

220-240

90

100

50

2.50

200

HID-D 1-10V 70 /S SON 220-240V

1

70

50/60

220-240

90

100

50

2.50

1000

Ordering and packing data

Type

Weight

Qty bulk

packing

Dimensions bulk packing

EAN code

bulk packing

EOC

8711500

HID-D 1-10V 100 /S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500931337

931320 30

HID-D 1-10V 100 /S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500749062

749055 30

HID-D 1-10V 150 /S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500538109

538093 30

HID-D 1-10V 150 /S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500538086

538079 30

HID-D 1-10V 70 /S CDO 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500931351

931344 30

HID-D 1-10V 70 /S SON 220-240V 50/60Hz

0.725 kg

10

39.8 cm x 16 cm x 11.1 cm

8711500927330

927323 30

Electrical installation notes

Mains operation
Rated mains voltage

220 - 240 V

With tolerances for performance
+6%-8%

203 - 254 V

With tolerances for operation

180 - 264 V

Mains frequency

50/60 Hz

Power factor 100% power

> 0.98

Power factor 35%, SON, 60%,
CDO, power

> 0.93

Earth leakage current

< 0,5 mA per driver

Overvoltage protection

48 hrs at 325 Vac
2 hrs at 366 Vac
5 min. at 400 Vac

Lamp operation
Operation frequency (typical)

125 Hz

Ignition voltage

3 - 4 kV

Cable capacity
SON

Max. 1 nF

CDO

Max. 200 pF

Air and creepage distance from any
(metal) part that may become live,
to earthed environment (class I) or
test finger (class II)

> 4 mm